Pull Stations

Picture
ESL (UTC Fire & Security) 103-20
Single-Action. Conventional. Hex key. Glass break rod can be installed internally. Trigger: NC Button is released. Will activate when opened. To reset, open station, restore handle to normal position and close station.

Currently shelved.
My Value: $10.00 Good condition. Small scratch on face. Nothing special.
Picture
Notifier BNG-1RS
Single-action. Conventional. Corbin CAT 15 key. Trigger: NC button is held down (open) in normal operation. Button is released (closed) when station is opened. Will activate when opened. To reset, unlock and close station, then lock closed.

Location as of August 2018: Garage.
My Value: $70.00 Very good condition. Rare and vintage. Notifier Emhart branding.
Picture
Notifier NBG-10L
Dual-action. Conventional. Notifier 17021 key. Trigger: NC button held down (open) by handle during normal operation. When handle is pulled, button is released (closed). Will activate when opened. To reset, open and close station.

Location as of August 2018: East-Side of Second Floor Hallway.
My Value: $19.00 Good condition. Has a tiny bit of paint on it. Common.
Picture
Silent Knight by Honeywell PS-DA
Dual-action. Conventional. Honeywell 1347 key. Trigger: NO switch. Switch is closed when handle is pushed in and pulled down, handle pushes toggle down. Will not activate when opened. To reset, open and close station. Handle will push toggle back into the up position.

Location as of August 2018: Basement.
My Value: $19.00 Good condition. Common.
Picture
Simplex 4099-9006
Dual-action. Addressable (Simplex). Simplex B key. Glass break rod can be installed internally. Trigger: NC button held down (open) in normal operation. Button is released (closed) when handle is pulled down. Will activate when opened. To reset, open and close station.

This is an addressable pull station, but I only connected the button. It is connected to a UTC Fire & Security 60-362N Wireless Door/Window sensor using terminals. A pretty clever way to make a wireless pull station!

​Location as of August 2018: Kitchen.
My Value: $24.00 Good condition. Common. No addressable module.
Picture
Edwards 270-SPO
Single-action. Conventional. Spring-loaded flathead screw. Glass break rod can be installed externally. Trigger: NO switch. Toggle is pushed up (closed) when handle is pulled. To reset, open station, flip toggle back down, hold handle in normal position and close station. Will not activate when opened.

Location as of August 2018: My Bedroom (Northeast Bedroom).
My Value: $18.00 Great condition. Very common and readily available.
You Can Also Find DJDiehl2K (Comments2010) on YouTube, TheFirePanel Forums, Twitter, Cemetech, and TI-Basic Dev!
The time is

© 2016 David Diehl / Comments2010 - All rights reserved - CC License

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

Hosted for free by Weebly - Create your own website

Powered by Create your own unique website with customizable templates.